97av,蜜桃视频下载,国产精品久久久久久婷婷,国产老妇伦国产熟女老妇久

     
  中文版 English
 
Hot news:
  News
  Company news
  Industry News
  Current news
Hot Product
IPX1 IPX2 Drip Waterproof Test...
UL1439 Sharp Edge Tester
BND-TPK05 IEC 60529 Test Probe...
IEC62368 test probe kit BND-TP...
IEC 61032 Standard Test Probe ...
IEC60320 EN60320 Appliances co...
UL 498 Standard Plugs and Rece...
IPX1 to IPX4 Drip rain test an...
Vertical horizontal vibration ...
IP5X IP6X Sand and dust proof ...
climate constant temperature a...
IPX1 to IPX9 waterproof testin...
 
 
Industry News
Home  -  News  -  Industry News
what is IP code? Solid particle protection and Liquid ingress protection
From: BONAD  Date: 2024-08-22 16:04:06


The IP code or ingress protection code indicates how well a device is protected against water and dust. It is defined by the International Electrotechnical Commission (IEC) under the international standard IEC 60529 which classifies and provides a guideline to the degree of protection provided by mechanical casings and electrical enclosures against intrusion, dust, accidental contact, and water. It is published in the European Union by the European Committee for Electrotechnical Standardization (CENELEC) as EN 60529.


Origin of the letters IP:

The standard aims to provide users more detailed information than vague marketing terms such as waterproof. For example, a cellular phone rated at IP67 is "dust resistant" and can be "immersed in 1 meter of freshwater for up to 30 minutes". Similarly, an electrical socket rated IP22 is protected against insertion of fingers and will not become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. IP22 or IP2X are typical minimum requirements for the design of electrical accessories for indoor use.

The digits indicate conformity with the conditions summarized in the tables below. The digit 0 is used where no protection is provided. The digit is replaced with the letter X when insufficient data has been gathered to assign a protection level. The device can become less capable; however, it cannot become unsafe.

There are no hyphens in a standard IP code. IPX-8 (for example) is thus an invalid IP code.

Code breakdown:



This table shows what each digit or part of the IP code represents.

IP codes

Code
letters
First Second Third Additional Supplementary
Solid particle protection Liquid ingress protection Mechanical impact resistance Other protections
IP (Ingress Protection) 0–6 or X 0–9 or X 0–9 Letter Letter
By definition Required Required No longer used Optional Optional

First digit: Solid particle protection

The first digit indicates the level of protection the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.

Level sized Effective against Description
X Unknown X means no data is available to specify a protection rating about this criterion.
0 No protection against contact and ingress of objects
1 > 50 mm
2.0 in
Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2 > 12.5 mm
0.49 in
Fingers or similar objects
3 > 2.5 mm
0.098 in
Tools, thick wires, etc.
4 > 1 mm
0.039 in
Most wires, slender screws, large ants, etc.
5 Dust protected Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the safe operation of the equipment.
6 Dust-tight No ingress of dust; complete protection against contact (dust-tight). A vacuum must be applied. Test duration of up to 8 hours based on airflow.

Second digit: Liquid ingress protection

The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.

The ratings for water ingress are not cumulative beyond IPX6. A device compliant with IPX7 (covering water immersion) is not necessarily compliant with IPX5 or IPX6 (covering exposure to water jets). A device that meets both tests is indicated by listing both tests separated by a slash, e.g. IPX5/IPX7.

Level Protection against Effective against Details
X Unknown X means no data is available to specify a protection rating concerning these criteria.
0 None No protection against ingress of water
1 Dripping water Dripping water (vertically falling drops) shall have no unsafe effect on the specimen when mounted upright onto a turntable and rotated at 1 RPM. Test duration: 10 minutes

Water equivalent to 1 mm (0.039 in) rainfall per minute

2 Dripping water when tilted at 15° Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. Test duration: 2.5 minutes for every direction of tilt (10 minutes total)

Water equivalent to 3 mm (0.12 in) rainfall per minute

3 Spraying water Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) a spray nozzle with a counterbalanced shield.

Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with a shield in place) for 5 minutes minimum.

For a spray nozzle:

Test duration: 1 minute per square meter for at least 5 minutes Water volume: 10 liters per minute (0.037 impgal/s) Pressure: 50–150 kPa (7.3–21.8 psi)

For an oscillating tube: Test duration: 10 minutes Water volume: 0.07 liters per minute (0.00026 impgal/s) per hole

4 Splashing of water Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either:

a) an oscillating fixture, or b) A spray nozzle with no shield. Test a) is conducted for 10 minutes. b) is conducted (without shield) for 5 minutes minimum.

Oscillating tube: Test duration: 10 minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)
5 Water jets Water projected by a nozzle (6.3 mm (0.25 in)) against enclosure from any direction shall have no harmful effects. Test duration: 1 minute per square meter for at least 3 minutes

Water volume: 12.5 litres per minute Pressure: 30 kPa (4.4 psi) at distance of 3 meters (9.8 ft)

6 Powerful water jets Water projected in powerful jets (12.5 mm (0.49 in)) against the enclosure from any direction shall have no harmful effects. Test duration: 1 minute per square meter for at least 3 minutes

Water volume: 100 liters per minute (0.37 impgal/s) Pressure: 100 kPa (15 psi) at distance of 3 meters (9.8 ft)

6K Powerful water jets with increased pressure Water projected in powerful jets (6.3 mm (0.25 in) nozzle) against the enclosure from any direction, under elevated pressure, shall have no harmful effects. Found in DIN 40050, and not IEC 60529. Test duration: at least 3 minutes

Water volume: 75 liters per minute (0.27 impgal/s) Pressure: 1,000 kPa (150 psi) at distance of 3 meters (9.8 ft)

7 Immersion, up to 1 meter (3 ft 3 in) depth Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 meter (3 ft 3 in) of submersion). Test duration: 30 minutes.

Tested with the lowest point of the enclosure 1,000 mm (39 in) below the surface of the water, or the highest point 150 mm (5.9 in) below the surface, whichever is deeper.

8 Immersion, 1 meter (3 ft 3 in) or more depth The equipment is suitable for continuous immersion in water under conditions which the manufacturer shall specify. However, with certain types of equipment, it can mean that water can enter but only so that it produces no harmful effects. The test depth and duration are expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion. Test duration: agreement with the manufacturer

Depth specified by the manufacturer, generally up to 3 meters (9.8 ft)

9 Powerful high-temperature water jets Protected against close-range high-pressure, high-temperature spray downs.

Smaller specimens rotate slowly on a turntable from 4 specific angles. Larger specimens are mounted in the intended position when used, no turntable required, and are tested freehand for at least 3 minutes at a distance of 0.15–0.2 meters (5.9 in – 7.9 in).

The specific requirements for the test nozzle are shown in figures 7, 8, & 9 of IEC (or EN) 60529.

This test is identified as IPx9 in IEC 60529.

Test duration: Fixture: 30 sec. in each of 4 angles (2 min. total), Freehand: 1 min/m2, 3 min. minimum

Water volume: 14–16 liters per minute (0.051–0.059 impgal/s) Pressure: 8–10 MPa (80–100 bar) at distance of 0.10–0.15 meters (3.9 in – 5.9 in) Water temperature: 80 °C (176 °F)

(All tests with the letter "K" are defined by ISO 20653 (replacing DIN 40050-9) and are not found in IEC 60529, except for IPx9, which is the same as the IP69K water test.)


 
 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\\\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com
 
欧美一级aaaaa久久久| 色婷婷综合中文久久一本 | 中国有多少黑人| 国产婷婷色一区二区三区在线| 精品亚洲一区二区三区四区五区高| 另类一区| 白丝兔女郎M开腿SM调教室| 天气| 国产白丝精品91爽爽久久| 偷拍自拍亚洲色图| 个旧市| 国产精品无码无需播放器| 国产精品怡红院在线观看 | 国产AV寂寞骚妇| 日韩在线成年视频人网站观看| 麻豆亚洲AV成人无码久久精品| 在线免费观看| 日韩精品极品视频在线观看免费| 日韩在线一区| 色网视频| av天堂首页| 吉木乃县| 蜜臀AV在线无码国产| 一区二区和激情视频| 国产精品无码a∨麻豆| 日韩VA中文字幕无码电影| 亚洲av无码日韩av无码网站冲| 粉嫩av.一区二区三区免费| 免看一级a一级久久爽爽| 日女人逼| 伊人久久大香线蕉av综合| 亚洲超碰97无码中文字幕 | 男人的天堂免费一区二区视频| 亚洲日本VA午夜在线影院| 亚洲va中文字幕不卡无码| 国模冰莲大胆自慰难受| 一本大道东京热无码一区| 天天有av| 北流市| 亚洲日韩色在线影院性色| 少妇无码av无码专区|