IEC61032 12.5mm steel ball IPX2X test probe
Basic Introduction:
1, According to the DIN40050
2, 12.5MM test probe is necessary appliance for household and similar electrical appliance of against electric shock protection test.
Technical parameters
1, Ball Diameter :12.5 mm
2, Baffle Plate Diameter:4 mm
3, Baffle Plate Thickness:10 mm
4, Handle Diameter: 4mm
Application:
1, The ball can not touch the live parts or not close to hazardous parts
2, In the test requirements of preventing from accessing to the hazardous parts,the test steel ball without thrust needs to be used with pushing tension meter,and steel body needs to exert 30±3N thrust on the protection layer.
IP2X 12.5mm Steel Ball Test Trobe Without Force
IP2X 12.5mm Steel Ball Test Trobe With 50N Force
|